张慧. 导乐镇痛仪在分娩镇痛中的应用效果分析[J]. 蚌埠医科大学学报, 2016, 41(7): 962-964. DOI: 10.13898/j.cnki.issn.1000-2200.2016.07.044
    引用本文: 张慧. 导乐镇痛仪在分娩镇痛中的应用效果分析[J]. 蚌埠医科大学学报, 2016, 41(7): 962-964. DOI: 10.13898/j.cnki.issn.1000-2200.2016.07.044
    ZHANG Hui. Application effect of Doula pain-abating machine on the analgesia in vaginal delivery[J]. Journal of Bengbu Medical University, 2016, 41(7): 962-964. DOI: 10.13898/j.cnki.issn.1000-2200.2016.07.044
    Citation: ZHANG Hui. Application effect of Doula pain-abating machine on the analgesia in vaginal delivery[J]. Journal of Bengbu Medical University, 2016, 41(7): 962-964. DOI: 10.13898/j.cnki.issn.1000-2200.2016.07.044

    导乐镇痛仪在分娩镇痛中的应用效果分析

    Application effect of Doula pain-abating machine on the analgesia in vaginal delivery

    • 摘要: 目的:分析导乐镇痛仪在分娩镇痛中的应用效果。方法:选择拟阴道分娩足月妊娠者240例,随机分为导乐仪组与对照组,各120例。对照组接受常规导乐护理,未给予任何镇痛办法;导乐仪组给予GT-4A导乐镇痛仪分娩。比较2组镇痛效果与第一产程、第二产程和第三产程时限、阴道分娩和剖宫产率及产后2 h出血量发生情况等。结果:导乐仪组的镇痛效果明显优于对照组(P<0.01),第一产程、第二产程时限均显著短于对照组(P<0.01),剖宫产率(7.5%)低于对照组(16.7%)(P<0.05)。2组产妇产后2 h出血量和第三产程差异均无统计学意义(P>0.05)。结论:导乐镇痛仪在分娩镇痛中能够发挥良好的镇痛效果,减轻患者痛苦,加快产程进展,降低剖宫产率,值得在临床上推广应用。

       

      Abstract: Objective: To investigate the effects of Doula pain-abating machine on the analgesia in vaginal delivery.Methods: Two hundred and forty full term pregnant women scheduled by vaginal delivery were randomly divided into the Doula pain-abating machine group and control group(120 cases each group).The Doula pain-abating machine group and control group were treated with GT-4A machine and conventional doula care during vaginal delivery,respectively.The pain-abating effects,labor time of the first stage,second stage and third stage,rates of vaginal delivery and cesarean section and bleeding after 2 hours of birth between two groups were compared.Results: The analgesia effects in Doula pain-abating machine group were significantly better than that in control group(P<0.01).The labor time of the first stage and second stage in Doula pain-abating machine group were significantly shorter than those in control group(P<0.01).The rate of cesarean section in Doula pain-abating machine group(7,5%) were less than that in control group(16.7%)(P<0.01).The differences of the bleeding amount after 2 hours of birth and labor time of the third stage between two groups were not statistically significant(P>0.05).Conclusions: The application of Doula pain-abating machine in labor analgesia can play good analgesia effects,relieve the pain of patients,accelerate the delivery process and decrease the rate of cesarean section,which is worthy of promotion in clinic.

       

    /

    返回文章
    返回